and repair according to Sec. 63.104(f)(1). ---------------------------------------------------------------------------------------------------------------- Table 6 to Subpart UUUU of Part 63.--Continuous Compliance With Operating Limits [As required in Sec. 63.5555(a), you must demonstrate continuous compliance with the appropriate operating limits according to the requirements in the following table:] ------------------------------------------------------------------------ you must demonstrate For the following control for the following continuous technique . . . operating limit . . compliance by . . . ----------------------------------------.------------------------------- 1. condenser................ maintain the daily collecting the average condenser condenser outlet outlet gas or gas or condensed condensed liquid liquid temperature temperature no data according to higher than the Sec. 63.5545; value established reducing the during the condenser outlet compliance gas temperature demonstration. data to daily averages; and maintaining the daily average condenser outlet gas or condensed liquid temperature no higher than the value established during the compliance demonstration. 2. thermal oxidizer......... maintain the daily collecting the average thermal thermal oxidizer oxidizer firebox firebox temperature temperature no data according to lower than the Sec. 63.5545; value established reducing the during the thermal oxidizer compliance firebox temperature demonstration. data to daily averages; and maintaining the daily average thermal oxidizer firebox temperature no lower than the value established during the compliance demonstration. 3. water scrubber........... maintain the daily collecting the average scrubber scrubber pressure pressure drop and drop and scrubber scrubber liquid liquid flow rate flow rate within data according to the values Sec. 63.5545; established during reducing the the compliance scrubber parameter demonstration. data to daily averages; and maintaining the daily scrubber parameter values within the values established during the compliance demonstration. 4. caustic scrubber......... maintain the daily collecting the average scrubber scrubber pressure pressure drop, drop, scrubber scrubber liquid liquid flow rate, flow rate, and and scrubber liquid scrubber liquid pH, pH, conductivity, conductivity, or or alkalinity data alkalinity within according to Sec. the values 63.5545; reducing established during the scrubber the compliance parameter data to demonstration. daily averages; and maintaining the daily scrubber parameter values within the values established during the compliance demonstration. 5. flare.................... maintain the collecting the pilot presence of a pilot flame data flame. according to Sec. 63.5545; and maintaining the presence of the pilot flame. [[Page 40089]] 6. biofilter................ maintain the daily collecting the average biofilter biofilter inlet gas inlet gas temperature, temperature, biofilter effluent biofilter effluent pH, and biofilter pH, and pressure pressure drop data drop within the according to Sec. values established 63.5545; reducing during the the biofilter compliance parameter data to demonstration. daily averages; and maintaining the daily biofilter parameter values within the values established during the compliance demonstration. 7. carbon absorber.......... maintain the collecting the data regeneration on regeneration frequency, total frequency, total regeneration stream regeneration stream mass or volumetric mass or volumetric flow during carbon flow during carbon bed regeneration bed regeneration and temperature of and temperature of the carbon bed the carbon bed after regeneration after regeneration (and within 15 (and within 15 minutes of minutes of completing any completing any cooling cycle(s)) cooling cycle(s)) for each for each regeneration cycle regeneration cycle within the values according to Sec. established during 63.5545; and the compliance maintaining carbon demonstration. absorber parameter values for each regeneration cycle within the values established during the compliance demonstration. 8. oil absorber............. maintain the daily collecting the average absorption absorption liquid liquid flow, flow, absorption absorption liquid liquid temperature, temperature, and and steam flow data steam flow within according to Sec. the values 63.5545; reducing established during the oil absorber the compliance parameter data to demonstration. daily averages; and maintaining the daily oil absorber parameter values within the values established during the compliance demonstration. 9. any of the control if using a CEMS, collecting CEMS techniques specified in maintain the daily emissions data at this table. average control the inlet and efficiency for each outlet of each control device no control device lower than the according to Sec. value established 63.5545; during the determining the compliance control efficiency demonstration. values for each control device using the inlet and outlet CEMS emissions data; reducing the control efficiency values for each control device to daily averages; and maintaining the daily average control efficiency for each control device no lower than the value established during the compliance demonstration. ------------------------------------------------------------------------ Table 7 to Subpart UUUU of Part 63.--Notifications [As required in 63.5490(c)(4), 63.5530(c), 63.5575, and 63.5595(b), you must submit the appropriate notifications specified in the following table] ------------------------------------------------------------------------ If you . . . then you must . . . ------------------------------------------------------------------------ 1. are required to conduct a submit a notification of intent to performance test. conduct a performance test at least 60 calendar days before the performance test is scheduled to begin, as specified in Secs. 63.7(b)(1) and 63.9(e). 2. wish to use an alternative submit a request to use alternative monitoring method. monitoring method no later than the notification of the initial performance test or CEMS performance evaluation or 60 days prior to any other initial compliance demonstration, as specified in Sec. 63.8(f)(4). 3. start up your affected submit an initial notification no later source before June 11, 2002. than 120 days after June 11, 2002, as specified in Sec. 63.9(b)(2). 4. start up your new or submit an initial notification no later reconstructed source on or than 120 days after you become subject after June 11, 2002. to this subpart, as specified in Sec. 63.9(b)(3). 5. cannot comply with the submit a request for extension of relevant standard by the compliance no later than 120 days applicable compliance date. before the compliance date, as specified in Secs. 63.9(c) and 63.6(i)(4). 6. are subject to special notify the Administrator of your requirements as specified in compliance obligations no later than Sec. 63.6(b)(3) and (4). the initial notification dates established in Sec. 63.9(b) for new sources not subject to the special provisions, as specified in Sec. 63.9(d). 7. are required to conduct notify the Administrator of the visible emission observations anticipated date for conducting the to determine the observations anticipated date for conducting the